Hi Axel,
And just to make sure that the horse is well and truly dead, after adding an
extra line to the script so that after making the black cylinder and then
loading the pdb, it creates another graphics molecule containing a cylinder
with the same endpoints (+/- 0.5 on the x axis), colored green with a larger
radius. The error reappears. See attached picture.
Cheers,
Seth
On 9/22/06, Dr. Seth Olsen <seth.olsen_at_gmail.com> wrote:
>
>
> Hi Axel,
>
> To be more specific about that last statement, if you change the script so
> that it loads the PDB after creating and drawing the graphics molecule, then
> things seem to work (in the sense that the graphics are not distorted. In
> case it might be of use, I'm attaching my .vmdrc file this time.
>
> Cheers,
>
> Seth
>
> On 9/22/06, Dr. Seth Olsen <seth.olsen_at_gmail.com> wrote:
> >
> >
> > Hi Axel,
> >
> > If this is the case, then something is definitely wrong. Attached
> > please find a python script named 'VMDAngstrom.py', a pdb file named '
> > AngstromScale.pdb', and a JPG file named 'Angstrom.jpg'. The pdb
> > contains 2 nitrogen atoms placed at (- 0.5,0.0,0.0) and (0.5,0.0,0.0).
> > The script loads this pdb (lines drawstyle), then creates a graphics
> > molecule and draws a thick black cylinder cylinder with endpoints at (-
> > 0.5,0.0,0.0) and (0.5,0.0,0.0). The JPG shows just what I got when I
> > ran the script.
> >
> > I am running a precompiled linux binary of VMD 1.8.5. I have pointed
> > PYTHONHOME to a precompiled python binary (compiled for 1.8.4, but there
> > is no current distribution as far as I can tell). My OS is FC5 running on a
> > P4.
> >
> > What's even more frustrating is that it seems that different results are
> > obtained if you create the graphics molecule, then load the pdb.
> > Regardless, I don't think this is the way VMD was intended to work.
> >
> > Cheers,
> >
> > Seth
> >
> > On 9/22/06, Axel Kohlmeyer < akohlmey_at_cmm.chem.upenn.edu> wrote:
> > >
> > > On 9/21/06, Dr. Seth Olsen <seth.olsen_at_gmail.com> wrote:
> > > >
> > > > Hi VMDers,
> > > >
> > > > I've been writing python scripts to visualize 3N dimensional vectors
> > > ( i.e .
> > > > molecular modes) as arrows attached to atoms. I've been having a
> > > lot of
> > > > problems with length distortions and after checking my code over
> > > several
> > > > times I think that the problem might be that I have assumed that VMD
> > > uses an
> > > > internal length scale that I am not. What are the units that VMD
> > > uses?
> > >
> > > all graphics objects are drawn on an angstrom scale.
> > >
> > > axel.
> > > >
> > > > Cheers,
> > > >
> > > > Seth
> > > >
> > > > --
> > > > ccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccms
> > > >
> > > > Dr Seth Olsen, PhD
> > > > Postdoctoral Fellow, Biomolecular Modeling Group
> > > > Centre for Computational Molecular Science
> > > > Australian Institute for Bioengineering and Nanotechnology (Bldg.
> > > 75)
> > > > The University of Queensland
> > > > Qld 4072, Brisbane, Australia
> > > >
> > > > tel (617) 3346 3976
> > > > fax (617) 33654623
> > > > email: s.olsen1_at_uq.edu.au
> > > > Web: www.ccms.uq.edu.au
> > > >
> > > > ccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccms
> > > > The opinions expressed here are my own and do not reflect the
> > > positions of
> > > > the University of Queensland.
> > >
> > >
> > > --
> > >
> > > =======================================================================
> > > Axel Kohlmeyer akohlmey_at_cmm.chem.upenn.edu
> > > http://www.cmm.upenn.edu
> > > Center for Molecular Modeling -- University of Pennsylvania
> > > Department of Chemistry, 231 S.34th Street, Philadelphia, PA
> > > 19104-6323
> > > tel: 1-215-898-1582, fax: 1-215-573-6233, office-tel: 1-215-898-5425
> > >
> > >
> > > =======================================================================
> > > If you make something idiot-proof, the universe creates a better
> > > idiot.
> > >
> >
> >
> >
> > --
> > ccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccms
> >
> > Dr Seth Olsen, PhD
> > Postdoctoral Fellow, Biomolecular Modeling Group
> > Centre for Computational Molecular Science
> > Australian Institute for Bioengineering and Nanotechnology (Bldg. 75)
> > The University of Queensland
> > Qld 4072, Brisbane, Australia
> >
> > tel (617) 3346 3976
> > fax (617) 33654623
> > email: s.olsen1_at_uq.edu.au
> > Web: www.ccms.uq.edu.au
> >
> > ccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccms
> > The opinions expressed here are my own and do not reflect the positions
> > of the University of Queensland.
> >
> >
>
>
> --
> ccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccms
>
> Dr Seth Olsen, PhD
> Postdoctoral Fellow, Biomolecular Modeling Group
> Centre for Computational Molecular Science
> Australian Institute for Bioengineering and Nanotechnology (Bldg. 75)
> The University of Queensland
> Qld 4072, Brisbane, Australia
>
> tel (617) 3346 3976
> fax (617) 33654623
> email: s.olsen1_at_uq.edu.au
> Web: www.ccms.uq.edu.au
>
> ccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccms
> The opinions expressed here are my own and do not reflect the positions of
> the University of Queensland.
>
>
-- ccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccms Dr Seth Olsen, PhD Postdoctoral Fellow, Biomolecular Modeling Group Centre for Computational Molecular Science Australian Institute for Bioengineering and Nanotechnology (Bldg. 75) The University of Queensland Qld 4072, Brisbane, Australia tel (617) 3346 3976 fax (617) 33654623 email: s.olsen1_at_uq.edu.au Web: www.ccms.uq.edu.au ccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccmsccms The opinions expressed here are my own and do not reflect the positions of the University of Queensland.
- Next message: Rob: "1.8.5: VASP plugin not correct"
- Previous message: Peter Freddolino: "Re: What unit system does VMD use?"
- In reply to: Dr. Seth Olsen: "Re: What unit system does VMD use?"
- Next in thread: Dr. Seth Olsen: "Re: What unit system does VMD use?"
- Reply: Dr. Seth Olsen: "Re: What unit system does VMD use?"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]