tilt colvar

From: JC Gumbart (gumbart_at_ks.uiuc.edu)
Date: Fri Nov 21 2014 - 11:09:55 CST

I think I still don’t understand this correctly. I have the case of a small helix with its reference state being parallel to the membrane (z) axis. I then want to sample a state where it’s parallel to the surface instead, meaning the tilt angle should be 90 deg. and cos(theta) = 0. Colvars tells me this is the case - for the frames of a given trajectory, “tilt” is around +/- 0.02. But when I look at the frames by eye, it’s clearly not the case. What I see is this (R is ref and C is current):

R C
| /
| /
| /
| /

when what I expect is this

R
|
|
|
| _ _ _ _ _ C

(I hope my ascii art comes through correctly).

When I calculate the angle for the case I actually observe, I get about 25 deg. What am I missing here?

Thanks!
JC