From: Siva Dasetty (sdasett_at_g.clemson.edu)
Date: Fri Sep 05 2014 - 15:24:45 CDT
Thank you for the reply. I forgot to add, but this note actually made me
realize that I don't need to do GBIS/SASA calculations for my graphene
surface as 1. it is not charged and 2. it is unnecessary.
So Is there any way that I can exclude GBIS for a particular group in NAMD?
In this case, exclude GBIS calculation for graphene and include for the
protein.
Thanks,
Siva
On Fri, Sep 5, 2014 at 4:16 PM, Jim Phillips <jim_at_ks.uiuc.edu> wrote:
>
> This message only applies to the GBIS implicit solvent code. The NAMD
> CUDA code for explicit solvent does support fixed atoms.
>
> I don't understand why this is and error. At the very least GBIS should
> be compatible with fixed atoms if fixedAtomsForces is set. I've revised
> the error test to automatically enable fixedAtomsForces and this should be
> available in the next nightly build. Please test tomorrow.
>
> Jim
>
>
>
> On Fri, 5 Sep 2014, Siva Dasetty wrote:
>
> Dear All,
>>
>> I am running a test simulation to check the performance of GBIS with CUDA.
>> My system involves graphene which is fixed and protein in implicit
>> solvent.
>> However when I try to run I get the following error " GBIS CUDA not yet
>> compatible with fixed atoms".
>>
>> Does that mean, NAMD cuda doesnt support fixed atoms yet or am I doing
>> something wrong?
>>
>> Thanks,
>> Siva
>>
>>
-- Siva Dasetty PhD Student Department of Chemical and Biomolecular Engineering Clemson University Clemson, SC 29634 USA